Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 469
Filtrar
1.
BMC Musculoskelet Disord ; 25(1): 315, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654251

RESUMO

PURPOSE: We aimed to evaluate the clinical efficacy of bilateral decompression with minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) assisted by an ultrasonic bone curette (UBC) for treating severe degenerative lumbar spinal stenosis (DLSS) and traditional tool laminectomy decompression MIS-TLIF for treating severe DLSS. METHODS: The clinical data of 128 patients with single-segment severe DLSS who were admitted between January 2017 and December 2021 were retrospectively analyzed. Among them, 67 patients were treated with unilateral fenestration and bilateral decompression MIS-TLIF using an ultrasonic bone curette (UBC group), whereas 61 patients were treated with unilateral fenestration and bilateral decompression MIS-TLIF using traditional tools (traditional group, control). A visual analog scale (VAS) was used to evaluate back and lower limb pain before the operation,immediate postoperative, and one week, 3, 6, 12, and 24 months after the operation. Oswestry disability index (ODI) and Zurich claudication score (ZCQ) were employed to evaluate the improvement in low back and lower limb function. At the last follow-up, the Bridwell bone graft fusion standard was utilized to evaluate bone graft fusion. RESULTS: The decompression time of laminectomy was significantly shorter in the UBC group than in the traditional group (control group), and the intraoperative blood loss and postoperative drainage volume were significantly less in those in the control group (P < 0.05). The VAS, ODI, and ZCQ scores of the two groups after the operation were significantly improved compared to those before the operation (P < 0.05). The UBC group had better VAS back scores than the control group immediate postoperative and one week after the operation(P < 0.05). The UBC group had better VAS lower limb scores than the control group immediate postoperative (P < 0.05).The incidence of perioperative complications, hospitalization time, dural sac cross-sectional area (CSA), and dural sac CSA improvement rate did not differ significantly between the two groups (P > 0.05). VAS and ODI scores did not differ significantly between the two groups before,three, six months, one year, and two years after surgery (P > 0.05). The ZCQ scores did not differ significantly between the two groups before the operation at one week, six months, one year, and two years after the operation (P > 0.05). According to the Bridwell bone graft fusion standard, bone graft fusion did not occur significantly between the two groups (P > 0.05) at the last follow-up. CONCLUSIONS: UBC unilateral fenestration bilateral decompression MIS-TLIF in treating severe DLSS can achieve clinical efficacy as traditional tool unilateral fenestration bilateral decompression MIS-TLIF and reduce intraoperative blood loss and postoperative drainage. It can also shorten the operation time, effectively reduce the work intensity of the operator, and reduce the degree of low back pain during short-term follow-ups. Therefore, this is a safe and effective surgical method.


Assuntos
Descompressão Cirúrgica , Vértebras Lombares , Fusão Vertebral , Estenose Espinal , Humanos , Estenose Espinal/cirurgia , Estenose Espinal/diagnóstico por imagem , Feminino , Masculino , Descompressão Cirúrgica/métodos , Vértebras Lombares/cirurgia , Vértebras Lombares/diagnóstico por imagem , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Fusão Vertebral/métodos , Fusão Vertebral/instrumentação , Resultado do Tratamento , Laminectomia/métodos , Transplante Ósseo/métodos , Índice de Gravidade de Doença , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Medição da Dor , Procedimentos Cirúrgicos Ultrassônicos/métodos , Procedimentos Cirúrgicos Ultrassônicos/instrumentação
2.
Radiol Imaging Cancer ; 6(1): e230074, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38099828

RESUMO

The management of cancer with alternative approaches is a matter of clinical interest worldwide. High-intensity focused ultrasound (HIFU) surgery is a noninvasive technique performed under US or MRI guidance. The most studied therapeutic uses of HIFU involve thermal tissue ablation, demonstrating both palliative and curative potential. However, concurrent mechanical bioeffects also provide opportunities in terms of augmented drug delivery and immunosensitization. The safety and efficacy of HIFU integration with current cancer treatment strategies are being actively investigated in managing primary and secondary tumors, including cancers of the breast, prostate, pancreas, liver, kidney, and bone. Current primary HIFU indications are pain palliation, complete ablation of localized earlystage tumors, or debulking of unresectable late-stage cancers. This review presents the latest HIFU applications, from investigational to clinically approved, in the field of tumor ablation. Keywords: Ultrasound, Ultrasound-High Intensity Focused (HIFU), Interventional-MSK, Interventional-Body, Oncology, Technology Assessment, Tumor Response, MR Imaging © RSNA, 2023.


Assuntos
Hipertermia Induzida , Neoplasias , Procedimentos Cirúrgicos Ultrassônicos , Masculino , Humanos , Fígado , Sistemas de Liberação de Medicamentos , Neoplasias/diagnóstico por imagem , Neoplasias/cirurgia
3.
Clín. investig. ginecol. obstet. (Ed. impr.) ; 50(4): [100885], Oct-Dic, 2023. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-226531

RESUMO

Many women across the world suffer from endometriosis. This disease should be staged by laparoscopy in order to know the extent of disease. Ultrasound may be a reliable diagnostic tool that could complement laparoscopy for endometriosis staging. The aim of this study is to perform a narrative review of the current status of studies comparing ultrasound findings and laparoscopic staging according to American Society Reproductive Medicine (ASRM) and ENZIAN classifications. A search in PubMed and Web of Science databases from 2004 to 2022 was performed using the following terms “endometriosis”, “ultrasound”, “laparoscopy”, “ENZIAN” and “ASRM”. We focused on the accuracy of sonography using laparoscopy as gold standard. Seven studies were ultimately included. We observed that ultrasound is accurate and correlates well with advanced stages in the case of ASRM classification, and correlates well with ENZIAN classification. However, some limitations came up. There is little scientific information out there regarding this specific topic. Some of the studies have a retrospective design and one of them has a small sample size. In addition to this, even if ultrasound could have a relevant role in staging deep endometriosis, this method is highly dependent on the operator's experience. We conclude that diagnostic performance of transvaginal ultrasound (TVS) for evaluating the extent of disease in women with pelvic endometriosis is high. However, evidence is still limited and further studies are needed.(AU)


Muchas mujeres en todo el mundo sufren de endometriosis. Esta enfermedad debe ser estadificada por laparoscopia para conocer la extensión de la enfermedad. La ecografía puede ser una herramienta de diagnóstico fiable que podría complementar la laparoscopia para la estadificación de la endometriosis. El objetivo de este estudio es realizar una revisión narrativa del estado actual de los estudios que comparan los hallazgos ecográficos y la estadificación laparoscópica según las clasificaciones de la Sociedad Americana de Medicina Reproductiva (ASRM) y ENZIAN. Se realizó una búsqueda en las bases de datos PubMed y Web of Science de 2004 a 2022 utilizando los siguientes términos: «endometriosis», «ultrasonido», «laparoscopia», «ENZIAN» y «ASRM». Nos enfocamos en la precisión de la ecografía utilizando la laparoscopia como estándar de oro. Finalmente, se incluyeron siete estudios. Observamos que la ecografía es precisa y se correlaciona bien con estadios avanzados en el caso de la clasificación ASRM, y se correlaciona bien con la clasificación ENZIAN. Sin embargo, surgieron algunas limitaciones. Hay poca información científica sobre este tema específico: algunos de los estudios tienen un diseño retrospectivo y uno de ellos tiene un tamaño de muestra pequeño. Además de esto, si bien la ecografía podría tener un papel relevante en la estadificación de la endometriosis profunda, este método depende en gran medida de la experiencia del operador. Concluimos que el rendimiento diagnóstico de la ecografía transvaginal para evaluar la extensión de la enfermedad en mujeres con endometriosis pélvica es alto. Sin embargo, la evidencia aún es limitada y se necesitan más estudios.(AU)


Assuntos
Humanos , Feminino , Endometriose/diagnóstico por imagem , Laparoscopia/métodos , Ultrassonografia/métodos , Achados Incidentais , Procedimentos Cirúrgicos Ultrassônicos , Estadiamento de Neoplasias
4.
Ann Surg Oncol ; 30(10): 6201-6214, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37606837

RESUMO

BACKGROUND: Breast-conserving surgery (BCS) still remains a blind surgery despite all available tumor localization methods. Intraoperative ultrasound (IOUS) allows real-time visualization during all resection phases. METHODS: This was a prospective observational cohort study conducted at the Veneto Institute of Oncology between January 2021 and June 2022. Patients with ductal carcinoma in situ, T1-2 invasive cancer, or post-neoadjuvant tumors, suitable for BCS, were recruited. All breast cancer lesion types were included, i.e. solid palpable, solid non-palpable, non-solid non-palpable, and post-neoadjuvant treatment residual lesions. Eligible participants were randomly assigned to either IOUS or traditional surgery (TS) in a 1:1 ratio. The main outcomes were surgical margin involvement, reoperation rate, closest margin width, main specimen and cavity shaving margin volumes, excess healthy tissue removal, and calculated resection ratio (CRR). RESULTS: Overall, 160 patients were enrolled: 80 patients were allocated to the TS group and 80 to the IOUS group. IOUS significantly reduced specimen volumes (16.8 cm3 [10.5-28.9] vs. 24.3 cm3 [15.0-41.3]; p = 0.015), with wider closest resection margin width (2.0 mm [1.0-4.0] vs. 1.0 mm [0.5-2.0] after TS; p < 0.001). Tumor volume to specimen volume ratio was significantly higher after IOUS (4.7% [2.5-9.1] vs. 2.9% [0.8-5.2]; p < 0.001). IOUS yielded significantly better CRR (84.5% [46-120.8] vs. 114% [81.8-193.2] after TS; p < 0.001), lower involved margin rate (2.5 vs. 15%; p = 0.009) and reduced re-excision rate (2.5 vs. 12.5%; p = 0.032). CONCLUSIONS: IOUS allows real-time resection margin visualization and continuous control during BCS. It showed clear superiority over TS in both oncological and surgical outcomes for all breast cancer lesion types. These results disfavor the paradigm of blind breast surgery.


Assuntos
Neoplasias da Mama , Procedimentos Cirúrgicos Ultrassônicos , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Margens de Excisão , Estudos Prospectivos , Ultrassonografia de Intervenção
5.
Eur Rev Med Pharmacol Sci ; 27(13): 5985-5992, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37458634

RESUMO

OBJECTIVE: The aim of this study was to assess the efficacy of ultrasound-guided Mammotome-assisted resection vs. conventional open surgery for benign breast tumors. PATIENTS AND METHODS: From July 2019 to December 2020, 134 suitable patients with benign breast cancers treated at our institution (Breast Surgery Department) were recruited and randomly allocated (1:1) to receive either Mammotome-assisted tumor excision (observation group) or open surgery (control group). The primary endpoint was clinical effectiveness, with surgical outcomes, complications, and satisfaction as secondary endpoints. RESULTS: Mammotome-assisted surgery resulted in shorter operative time, scar length, and postoperative healing time and less intraoperative bleeding volume vs. open surgery (p<0.001). Mammotome-assisted surgery was associated with a significantly higher clinical efficacy vs. open surgery (p<0.05). Patients receiving Mammotome-assisted surgery had a lower incidence of complications vs. those given open surgery (p<0.05). A significantly higher satisfaction was observed in patients given Mammotome-assisted surgery vs. open surgery (p<0.05). CONCLUSIONS: In comparison to standard open surgery, ultrasound-guided Mammotome-assisted surgery provides a viable alternative for breast benign tumor removal with superior efficacy, shorter operating time, less trauma, higher safety, fewer complications, and higher patient satisfaction.


Assuntos
Neoplasias da Mama , Procedimentos Cirúrgicos Ultrassônicos , Feminino , Humanos , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Neoplasias da Mama/patologia , Resultado do Tratamento , Ultrassonografia de Intervenção/métodos
6.
Stereotact Funct Neurosurg ; 101(4): 223-231, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37379811

RESUMO

INTRODUCTION: Transcranial magnetic resonance-guided focused ultrasound surgery (TcMRgFUS) has the advantage of allowing immediate evaluation of therapeutic effects after each sonication and intraoperative magnetic resonance imaging (MRI) to visualize the lesion. When the image shows that the lesion has missed the planned target and the therapeutic effects are insufficient, the target of the subsequent ablation can be finely adjusted based on the image. The precision of this adjustment is determined by the image quality. However, the current intraoperative image quality with a 3.0T MRI system is insufficient for precisely detecting the lesion. Thus, we developed and validated a method for improving intraoperative image quality. METHODS: Because intraoperative image quality is affected by transmitter gain (TG), we acquired T2-weighted images (T2WIs) with two types of TG: the automatically adjusted TG (auto TG) and the manually adjusted TG (manual TG). To evaluate the character of images with 2 TGs, the actual flip angle (FA), the image uniformity, and the signal-to-noise ratio (SNR) were measured using a phantom. Then, to assess the quality of intraoperative images, T2WIs with both TGs were acquired during TcMRgFUS for 5 patients. The contrast-to-noise ratio (CNR) of the lesion was retrospectively estimated. RESULTS: The images of the phantom with the auto TG showed substantial variations between the preset and actual FAs (p < 0.01), whereas on the images with the manual TG, there were no variations between the two FAs (p > 0.05). The total image uniformity was considerably lower with the manual TG than with the auto TG (p < 0.01), indicating that the image's signal values with the manual TG were more uniform. The manual TG produced significantly higher SNRs than the auto TG (p < 0.01). In the clinical study, the lesions were clearly detected in intraoperative images with the manual TG, but they were difficult to identify in images with the auto TG. The CNR of lesions in images with manual TG was considerably higher than in images with auto TG (p < 0.01). CONCLUSION: Regarding intraoperative T2WIs using a 3.0T MRI system during TcMRgFUS, the manual TG method improved image quality and delineated the ablative lesion more clearly than the current method with auto TG.


Assuntos
Imageamento por Ressonância Magnética , Procedimentos Cirúrgicos Ultrassônicos , Humanos , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Procedimentos Cirúrgicos Ultrassônicos/métodos , Espectroscopia de Ressonância Magnética
7.
Parkinsonism Relat Disord ; 111: 105431, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37164870

RESUMO

Magnetic resonance-guided focused ultrasound (MRgFUS) is a new surgical treatment for Parkinson's disease (PD). Previous experience with radiofrequency lesionectomy and deep brain stimulation (DBS) has identified several candidate targets for MRgFUS intended to alleviate the motor symptoms of PD. The main advantage of MRgFUS is that it is incisionless. MRgFUS has certain limitations and is associated with adverse effects. The present study reviews the literature on conventional surgical interventions for PD, discusses recent studies on MRgFUS, and the comparison between DBS and MRgFUS for PD. The reviews aims to provide an essential reference for neurologists to select the appropriate treatments for patients with PD.


Assuntos
Estimulação Encefálica Profunda , Tremor Essencial , Doença de Parkinson , Procedimentos Cirúrgicos Ultrassônicos , Humanos , Doença de Parkinson/diagnóstico por imagem , Doença de Parkinson/cirurgia , Resultado do Tratamento , Tremor Essencial/terapia , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
8.
Neurosurgery ; 93(3): 524-538, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37010324

RESUMO

BACKGROUND: Focused ultrasound (FUS-T) and stereotactic radiosurgery thalamotomy (SRS-T) targeting the ventral intermediate nucleus are effective incisionless surgeries for essential tremor (ET). However, their efficacy for tremor reduction and, importantly, adverse event incidence have not been directly compared. OBJECTIVE: To present a comprehensive systematic review with network meta-analysis examining both efficacy and adverse events (AEs) of FUS-T vs SRS-T for treating medically refractory ET. METHODS: We conducted a systematic review and network meta-analysis according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, using the PubMed and Embase databases. We included all primary FUS-T/SRS-T studies with approximately 1-year follow-up, with unilateral Fahn-Tolosa-Marin Tremor Rating Scale or Clinical Rating Scale for Tremor scores prethalamotomy/post-thalamotomy and/or AEs. The primary efficacy outcome was Fahn-Tolosa-Marin Tremor Rating Scale A+B score reduction. AEs were reported as an estimated incidence. RESULTS: Fifteen studies of 464 patients and 3 studies of 62 patients met inclusion criteria for FUS-T/SRS-T efficacy comparison, respectively. Network meta-analysis demonstrated similar tremor reduction between modalities (absolute tremor reduction: FUS-T: -11.6 (95% CI: -13.3, -9.9); SRS-T: -10.3 (95% CI: -14.2, -6.0). FUS-T had a greater 1-year adverse event rate, particularly imbalance and gait disturbances (10.5%) and sensory disturbances (8.3%). Contralateral hemiparesis (2.7%) often accompanied by speech impairment (2.4%) were most common after SRS-T. There was no correlation between efficacy and lesion volume. CONCLUSION: Our systematic review found similar efficacy between FUS-T and SRS-T for ET, with trend toward higher efficacy yet greater adverse event incidence with FUS-T. Smaller lesion volumes could mitigate FUS-T off-target effects for greater safety.


Assuntos
Tremor Essencial , Radiocirurgia , Procedimentos Cirúrgicos Ultrassônicos , Humanos , Tremor Essencial/cirurgia , Imageamento por Ressonância Magnética , Radiocirurgia/efeitos adversos , Tálamo/cirurgia , Resultado do Tratamento , Tremor/cirurgia , Metanálise em Rede
9.
Int J Hyperthermia ; 40(1): 2184397, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36888994

RESUMO

OBJECTIVE: To develop and validate a radiomics nomogram for predicting the survival of patients with pancreatic ductal adenocarcinoma (PDAC) after receiving high-intensity focused ultrasound (HIFU) treatment. METHODS: A total of 52 patients with PDAC were enrolled. To select features, the least absolute shrinkage and selection operator algorithm were applied, and the radiomics score (Rad-Score) was obtained. Radiomics model, clinics model, and radiomics nomogram model were constructed by multivariate regression analysis. The identification, calibration, and clinical application of nomogram were evaluated. Survival analysis was performed using Kaplan-Meier (K-M) method. RESULTS: According to conclusions made from the multivariate Cox model, Rad-Score, and tumor size were independent risk factors for OS. Compared with the clinical model and radiomics model, the combination of Rad-Score and clinicopathological factors could better predict the survival of patients. Patients were divided into high-risk and low-risk groups according to Rad-Score. K-M analysis showed that the difference between the two groups was statistically significant (p < 0.05). In addition, the radiomics nomogram model indicated better discrimination, calibration, and clinical practicability in training and validation cohorts. CONCLUSION: The radiomics nomogram effectively evaluates the prognosis of patients with advanced pancreatic cancer after HIFU surgery, which could potentially improve treatment strategies and promote individualized treatment of advanced pancreatic cancer.


Assuntos
Adenocarcinoma , Neoplasias Pancreáticas , Procedimentos Cirúrgicos Ultrassônicos , Humanos , Nomogramas , Prognóstico , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/cirurgia , Neoplasias Pancreáticas
10.
Acad Radiol ; 30 Suppl 2: S220-S226, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36624022

RESUMO

RATIONALE AND OBJECTIVES: The purpose of this study was to explore the feasibility of magnetic resonance imaging-guided focused ultrasound surgery (MRgFUS) for the treatment of an adenomyosis model of Bama pigs and the changes in the level of oxytocin receptor (OTR), vascular endothelial growth factor (VEGF), and cyclooxygenase-2 (COX-2) in the myometrium tissues of Bama pigs after MRgFUS. MATERIALS AND METHODS: Three Bama pig models of adenomyosis were established by autologous endometrial implantation and evaluated by magnetic resonance imaging, computed tomography, and hematoxylin-eosin (H&E) staining. After the successful construction of the model, the pigs underwent MRgFUS. Before the modeling surgery, three months after the modeling, and two months after ablation, the myometrium tissues were clipped, then embedded and H&E stained for immunohistochemical examination. The average optical density of OTR, VEGF, and COX-2 were semi-quantitatively analyzed. RESULTS: The adenomyosis models were established in all Bama pigs and confirmed by magnetic resonance imaging, computed tomography and H&E staining. Magnetic resonance imaging and computed tomography examination showed that the uterine wall at the modeling site was significantly thickened with uneven enhancement after contrast injection. All Bama pigs with adenomyosis lesions underwent MRgFUS without complications. The expression level of OTR and COX-2 in the myometrium increased three months after modeling surgery and decreased two months after MRgFUS. The expression level of VEGF decreased two months after MRgFUS. CONCLUSION: Autologous endometrial implantation is effective in establishing the adenomyosis model of Bama pigs. It is feasible to treat adenomyosis in the Bama pig model with MRgFUS. The levels of OTR, COX-2 and VEGF in the local myometrium decreased after MRgFUS, which may be associated with symptom relief after treatment.


Assuntos
Adenomiose , Procedimentos Cirúrgicos Ultrassônicos , Humanos , Feminino , Animais , Suínos , Adenomiose/diagnóstico por imagem , Adenomiose/cirurgia , Adenomiose/complicações , Fator A de Crescimento do Endotélio Vascular , Ciclo-Oxigenase 2 , Imageamento por Ressonância Magnética
11.
Artigo em Inglês | MEDLINE | ID: mdl-36241027

RESUMO

Metastatic carcinoma of unknown primary (CUP) to cervical lymph nodes represents less than 5% of all head and neck malignancies. Recent publications support the use of transoral surgery during the diagnosis work-up, and transoral endoscopic ultrasonic surgery represent a recently described alternative technique in transoral surgery. A pilot study to assess the feasibility of trans-oral ultrasonic base of tongue (BOT) mucosectomy and bilateral tonsillectomy approach in CUP diagnosis work-up was conducted. Ten patients were included consecutively. In 2 cases (20%) the primary was found, in one case in the right tonsil, and another one in the left BOT. According to our results, the use of trans-oral ultrasonic surgery to perform the base of tongue mucosectomy and bilateral tonsillectomy in CUP patient's during the diagnosis work-up represents an effective option in patients with good anatomical exposure.


Assuntos
Carcinoma , Cirurgia Endoscópica por Orifício Natural , Neoplasias Primárias Desconhecidas , Procedimentos Cirúrgicos Robóticos , Procedimentos Cirúrgicos Ultrassônicos , Humanos , Neoplasias Primárias Desconhecidas/cirurgia , Neoplasias Primárias Desconhecidas/etiologia , Neoplasias Primárias Desconhecidas/patologia , Ultrassom , Projetos Piloto , Procedimentos Cirúrgicos Robóticos/métodos , Cirurgia Endoscópica por Orifício Natural/métodos
12.
Eur Radiol ; 33(2): 1465-1474, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36074263

RESUMO

OBJECTIVES: MR imaging-guided focused ultrasound surgery (MRgFUS) is an emerging non-invasive treatment. It is helpful in investigating the mid-term grading efficacy and safety of MRgFUS, and possible risk factors in participants with painful bone metastases. METHODS: This four-center prospective study enrolled 96 participants between June 2016 and May 2019 with painful bone metastases. The Numerical Rating Scale (NRS), Brief Pain Inventory-Quality of Life (BPI-QoL) score, morphine equivalent daily dose (MEDD), and the adverse events (AEs) were recorded before and at 1 week, 1 month, 2 months, and 3 months after MRgFUS. The repeated ANOVA tests were used to analyze the change in NRS and BPI-QoL, and logistic regression analysis was used to analyze the possible risk factors. RESULTS: A total of 82 participants completed the 3-month follow-up period. And 16 (19.5%) participants were complete responders (CR), 46 (56.1%) participants were effective responders (ER), and the other 20 (24.4%) participants were non-responders (NR). The NRS (2.67 ± 2.47 at 3 months compared to 6.38 ± 1.70 before treatment) and BPI-QoL score (3.11 ± 2.51 at 3 months compared to 5.40 ± 1.85 before treatment) significantly decreased after the treatment at all time points (p < 0.001). Eleven adverse events were recorded and they were all cured within 1 to 52 days after treatment. The non-perfused volume (NPV) ratio (p = 0.001) and the bone metastases lesion type (p = 0.025) were the key risk factors. CONCLUSIONS: MRgFUS can be used as a non-invasive, effective, and safe modality to treat painful bone metastases. NPV ratio and the lesion type may be used as affecting factors to predict the mid-term efficacy of MRgFUS. KEY POINTS: • MRgFUS can be considered a non-invasive, effective, and safe modality to treat painful bone metastases. • The NRS and BPI-QoL score at 1 week, 1 month, 2 months, and 3 months all decreased significantly (p < 0.001) after receiving MRgFUS. Among 82 participants, 16 (19.5%) were complete responders, 46 (56.1%) were effective responders, and the other 20 (24.4%) were non-responders. • According to logistic regression analysis, non-perfused volume ratio and the bone metastases lesion type were the affecting factors to predict the mid-term efficacy of MRgFUS. The adjusted OR of non-perfused volume ratio was 0.86 (p = 0.001), and osteoblastic lesion type was 0.06 (p = 0.025).


Assuntos
Neoplasias Ósseas , Ablação por Ultrassom Focalizado de Alta Intensidade , Procedimentos Cirúrgicos Ultrassônicos , Humanos , Qualidade de Vida , Manejo da Dor , Estudos Prospectivos , Dor/etiologia , Imageamento por Ressonância Magnética , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/cirurgia , Ablação por Ultrassom Focalizado de Alta Intensidade/efeitos adversos , Espectroscopia de Ressonância Magnética , Resultado do Tratamento
15.
Sci Rep ; 12(1): 1719, 2022 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-35110589

RESUMO

Surgical smoke is a common chemical hazard produced from the use of electrocautery, laser, or ultrasonic scalpels during surgery. It has been proved harmful to medical personnel. Thus, it is important to monitor surgical smoke concentrations in the operating room. In the past decade, many researches regarding surgical smoke were discussed in different professional healthcare fields, but few showed the correlation between surgical smoke and otolaryngology surgery. In this study, the concentrations of particulate matter and formaldehyde were measured during thirty cases of several types of otolaryngology surgery in a regional research hospital in Taiwan. The concentrations of 0.3 µm and 0.5 µm particulate matter raised rapidly in the main knife range at the beginning of the electrocautery knife used, and then decreased by half after 5-10 min of use. The concentrations of formaldehyde were ranged from 1 to 2 ppm during the surgery, which is higher than the permissible exposure limit. While many medical staffs are working in the operating room and are exposed to the smoke hazard, effective strategies for collecting and eliminating the smoke should be taken in all medical facilities.


Assuntos
Eletrocoagulação , Formaldeído/análise , Exposição por Inalação , Terapia a Laser , Exposição Ocupacional , Salas Cirúrgicas , Procedimentos Cirúrgicos Otorrinolaringológicos , Fumaça/análise , Procedimentos Cirúrgicos Ultrassônicos , Eletrocoagulação/efeitos adversos , Eletrocoagulação/instrumentação , Monitoramento Ambiental , Formaldeído/efeitos adversos , Humanos , Exposição por Inalação/efeitos adversos , Terapia a Laser/efeitos adversos , Terapia a Laser/instrumentação , Exposição Ocupacional/efeitos adversos , Saúde Ocupacional , Duração da Cirurgia , Procedimentos Cirúrgicos Otorrinolaringológicos/efeitos adversos , Procedimentos Cirúrgicos Otorrinolaringológicos/instrumentação , Medição de Risco , Fumaça/efeitos adversos , Taiwan , Fatores de Tempo , Procedimentos Cirúrgicos Ultrassônicos/efeitos adversos , Procedimentos Cirúrgicos Ultrassônicos/instrumentação
16.
Medicine (Baltimore) ; 101(2): e28518, 2022 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-35029207

RESUMO

OBJECTIVE: In current literature, no studies evaluated effect of energy-based vessel-sealing-devices on quality of life after sutureless total thyroidectomies. This study aimed to identify any potential differences between two energy-based vessel-sealing-devices (Harmonic Focus, Ligasure LF1212) in patients with benign thyroid disorders who underwent sutureless total thyroidectomy. MATERIALS AND METHODS: Differences in quality of life of patients were evaluated using data obtained by Thy-PRO-39-Tr questionnaire prior to and four-week after surgery. Total and domain-based alterations in quality of life were compared between groups according to energy-based vessel-sealing-devices type (Group L, Group H). Additionally, data including demographics, height, weight, body mass index, neck circumference, sternomental distance were collected. RESULTS: Of 1032 patients, 200 were eligible for study, at the end 193 were analysed. There were no differences between groups in terms of age, sex, body mass index, tobacco use. Analysis did not reveal any differences in overall quality of life between groups (P = .42). However, in "eye symptoms" (P < .001) and "cognitive functions" (P = .002) domains, Harmonic provided statistically improved quality of life. Effect on cognitive function was greater in patients of advanced age. CONCLUSIONS: Especially in elderly patients with worsening eye conditions and cognitive functions, use of Harmonic may enhance patients' outcome by increasing quality of life in addition to optimizing surgical outcome when compared to Ligasure.


Assuntos
Qualidade de Vida/psicologia , Instrumentos Cirúrgicos , Técnicas de Sutura/instrumentação , Doenças da Glândula Tireoide/cirurgia , Tireoidectomia/instrumentação , Procedimentos Cirúrgicos Ultrassônicos/instrumentação , Idoso , Feminino , Hemostasia Cirúrgica , Humanos , Masculino , Pessoa de Meia-Idade , Tireoidectomia/efeitos adversos , Resultado do Tratamento , Procedimentos Cirúrgicos Ultrassônicos/efeitos adversos
17.
Oral Oncol ; 124: 105643, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34902808

RESUMO

INTRODUCTION/BACKGROUND: With the advent of TransOral Robotic Surgery (TORS) the ease of transoral procedures has been dramatically improved. TORS is already established for its feasibility, functional and oncological outcomes for selected lesions of oral cavity, oropharynx and laryngopharynx. This study reports on preliminary results with TransOral UltraSonic Surgery (TOUSS) for oncologic resections of oral cavity, oropharyngeal and supraglottic malignancies. MATERIALS AND METHODS: Eighteen patients with malignancies of oral cavity, oropharynx and supraglottis underwent TOUSS with simultaneous neck dissection and adjuvant therapy as indicated, from January 2018 to April 2019. Essential equipment included the FK-retractor (Gyrus Medical, Tuttilngen, Germany) for TransOral exposure, the Olympus ENDOEYE Flex 5 mm 2D/10 mm 3D deflecting tip video laparoscopes, and 35 cm long ultrasonic harmonic scalpel (Thunderbeat). Parameters evaluated include tumor staging, mouth opening, TOUSS setup time, TOUSS primary removal time, surgical margins, blood transfusions, tracheostomy, postoperative complications, enteral feeding and resumption of oral diet, duration of hospital stay, and survival outcomes. RESULTS: Eighteen patients underwent complete TransOral UltraSonic Surgery (TOUSS), with simultaneous unilateral or bilateral neck dissection. No procedure was abandoned intraoperatively due to difficulty in extirpation of the tumor. Margins were negative for ten patients (55.6%), close in five (27.8%), and positive in three patients (16.7%). Average TOUSS set-up time was 22.5 min (range, 10-30 min) and average TOUSS primary tumor removal time was 35.3 min (range, 15-60 min). Patients started tolerating oral feeds even in the second post op day (mean 6 days), and transitioning to complete oral feeds with removal of the nasogastric tube was achieved in all (mean, 16 days). The average hospital stay was 7.4 days (range 2-16 days). Secondary hemorrhage occurred in two cases and required an emergency tracheostomy and ligation of lingual artery. Minor cervicopharyngeal fistula occurred in four cases and settled in all with conservative non-surgical treatment. Overall survival at 3 years was 70.5%, and disease-specific survival was 94.4%. CONCLUSION: TransOral UltraSonic Surgery (TOUSS) is a safe and sound alternative method of endoscopic surgical treatment of oral cavity, oropharynx and supraglottic neoplasms. Advantages of this technique include faster resection time, intraoperative assistance from Narrow Band Imaging, easy affordability compared to TORS, and excellent functional outcomes.


Assuntos
Neoplasias Laríngeas , Neoplasias Orofaríngeas , Procedimentos Cirúrgicos Ultrassônicos , Estudos de Viabilidade , Humanos , Neoplasias Laríngeas/cirurgia , Margens de Excisão , Boca/cirurgia , Neoplasias Orofaríngeas/cirurgia , Orofaringe , Estudos Prospectivos , Resultado do Tratamento
18.
Minim Invasive Ther Allied Technol ; 31(5): 728-736, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33853487

RESUMO

INTRODUCTION: Evidence on the biological danger associated with surgical plume is lacking. We examined whether surgical plume, generated by the energy devices ultrasonically activated scalpel (US) or electrocautery (EC) contains virus-related substances. MATERIAL AND METHODS: Experiment 1, ex-vivo model: Tumor mass of a hepatocellular carcinoma line was prepared in a Nod/SCID mouse. Surgical plume generated on the mass by US or EC was collected and detection of HBs gene fragment and antigens (HBsAg or AFP) was conducted. Experiment 2, clinical specimen: Detection of HBV-DNA and HBsAg was conducted following the collection of surgical plume generated from clinically obtained liver specimens from six HBV-associated hepatocellular carcinoma patients. RESULTS: Experiment 1: HBs gene fragment was detected in the solutions regardless of the device used. HBsAg was detected in US and EC solutions and AFP was also detected in a US solution. Experiment 2: HBV-DNA was detected in both devices, in all three cases whose preoperative serum HBV-DNA was positive. In the other serum-negative cases, HBV-DNA was not detected. While serum HBsAg was positive in five of six cases, it was not detected in any solution. CONCLUSIONS: DNA fragments or antigens of virus can exist in the surgical plume generated by EC or US.


Assuntos
Aerossóis , Carcinoma Hepatocelular , Vírus da Hepatite B , Neoplasias Hepáticas , Aerossóis/análise , Animais , Carcinoma Hepatocelular/cirurgia , DNA Viral/isolamento & purificação , Eletrocoagulação , Antígenos de Superfície da Hepatite B/isolamento & purificação , Vírus da Hepatite B/isolamento & purificação , Humanos , Neoplasias Hepáticas/cirurgia , Camundongos , Camundongos SCID , Procedimentos Cirúrgicos Ultrassônicos , alfa-Fetoproteínas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...